Technical Data Measure Head | |
Sensor head: | Statox 501S |
Measuring principle: | electrochemical |
Operation temperature: | -20 – +50°C |
Humidity: | 20 – 95 % r.H., not condensing |
Pressure: | 900 – 1100 hPa |
Power supply: | 24 VDC |
Connections: | 3- or 5- Wire |
Output: | 4 – 20 mA |
Dimensions (HxWxD): | 125 x 125 x 85 mm |
Weight: | 470 g |
Housing material: | ABS chrome plated |
Ingress protection EN 60529: | IP54 |
ATEX marking: | II 2 G EEx ib IIC T5 |
Max. wire length: | up to 2400 m, assembly in zone N up to 570 m with Repeater, assembly in zone 1 |
Technical Data – Sensors | |||
Sensor |
Measure Range | Working temperature | Relative humidity |
Chlorine Cl2 | 0 – 3 / 5 ppm | -20 – +50 °C | 20 – 95 % |
Carbon monoxide CO | 0 – 100 / 300 ppm | -20 – +50 °C | 20 – 90 % |
Phosgene COCl2 | 0 – 0,3 / 1,0 / 15/ 100 ppm | -20 – +50 °C | 20 – 95 % |
Hydrogen H2 | 0 – 150 / 300 / 1000 ppm | -20 – +50 °C | 20 – 90 % |
Hydrogen sulphide H2S | 0 – 100 ppm | -20 – +50 °C | 20 – 95 % |
Hydrogen chloride HCl | 0 – 50 ppm | -20 – +50 °C | 20 – 95 % |
Hydrogen cyanide HCN | 0 – 20 / 30 / 100 ppm | -20 – +50 °C | 20 – 95 % |
Hydrogen fluoride HF | 0 – 10 ppm | -20 – +50 °C | 20 – 95 % |
Hydrazine N2H4 | 0 – 1,0 ppm | -20 – +50 °C | 20 – 95 % |
Ammonia NH3 | 0 – 150 ppm | -20 – +50 °C | 15 – 95 % |
Nitrogen dioxide NO2 | 0 – 10 / 50 ppm | -20 – +50 °C | 20 – 95 % |
Oxygen O2 | 2 – 35 % | -20 – +50 °C | 20 – 95 % |
Ozone O3 | 0 – 1,0 ppm | -20 – +50 °C | 20 – 90 % |